faq
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| faq [2022/03/23 15:50] – added jumper settings reno | faq [2023/11/30 14:32] (current) – reno | ||
|---|---|---|---|
| Line 5: | Line 5: | ||
| **A:** Ensure brightest part of the band of light is sitting in the middle of the Iris. There are two ways to accomplish this.++++ More...| | **A:** Ensure brightest part of the band of light is sitting in the middle of the Iris. There are two ways to accomplish this.++++ More...| | ||
| - Manually adjusting by loosening the zenith shaft and moving the shaft until the band of light lines up as shown in the picture. \\ {{ : | - Manually adjusting by loosening the zenith shaft and moving the shaft until the band of light lines up as shown in the picture. \\ {{ : | ||
| - | - Doing a ZI, this will do a shorten DI where it only checks for the zenith position.\\{{ | + | - Doing a ZI, this will do a shorten DI where it only checks for the zenith position.\\ {{: |
| ++++ | ++++ | ||
| Line 18: | Line 18: | ||
| ==== Old Electronics ==== | ==== Old Electronics ==== | ||
| **Q:** What are the differences between new vs old temperature circuit on the clock board?\\ | **Q:** What are the differences between new vs old temperature circuit on the clock board?\\ | ||
| - | **A:** Note the resistors on the top left of the boards below (New Vs Old). New temperature circuits, some resistors has been replaced with a jumper wire. | + | **A:** Note the resistors on the top left of the boards below (New Vs Old). New temperature circuits, some resistors has been replaced with a jumper wire.\\ |
| - | {{: | + | {{: |
| **Q:** What is the differences between new vs old temperature circuit on the SPS board?\\ | **Q:** What is the differences between new vs old temperature circuit on the SPS board?\\ | ||
| Line 50: | Line 50: | ||
| ===== Software ===== | ===== Software ===== | ||
| - | |||
| - | **Q:** How do I remote into _______ site?\\ | ||
| - | **A:** You can connect to most site with [[https:// | ||
| - | //Note:// SPO requires a few extra steps, see [[spo# | ||
| **Q:** How do I launch a GUI via remote ssh?\\ | **Q:** How do I launch a GUI via remote ssh?\\ | ||
| Line 61: | Line 57: | ||
| **A:** Type: :%s/^M/ /g\\ (note to type in ^M < | **A:** Type: :%s/^M/ /g\\ (note to type in ^M < | ||
| - | ===== Calculators | + | ===== DosBox Key Mapper |
| - | **Q: ** How do you convert elevation to pressure? | + | https://www.dosbox.com/wiki/Mapper\\ |
| - | **A:** < | + | For keyboard issues where up/down/left/right is not working, try setting setting |
| - | + | < | |
| - | ===== Brewer Processing ===== | + | usescancodes=false</ |
| - | **Q:** Where do you check what constants file is being used for the data processing? | + | |
| - | **A: | + | |
| - | \\wontlabj105896\C\Uvr</ | + | |
faq.1648050654.txt.gz · Last modified: 2022/03/23 15:50 by reno