hvb
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revision | |||
| hvb [2022/08/25 18:45] – reno | hvb [2023/11/30 13:25] (current) – external edit 127.0.0.1 | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| - | ===== HVB ===== | + | ===== HVB (Depreciated)===== |
| + | NOTE: As of version 7.33, HVB has been depreciated. [[hv|HV]] will be used for both multiboard & single board electronics. | ||
| === High Voltage Test (MB) === | === High Voltage Test (MB) === | ||
| The HVB command | The HVB command | ||
| Line 16: | Line 17: | ||
| - Turn the brewer on | - Turn the brewer on | ||
| - Run the command " | - Run the command " | ||
| - | - Follow the dosbox prompt | + | - Follow the dosbox prompt |
| - During the lamp warm up, set the multimeter to the voltage setting, and insert the leads to GND and HV on the panel beside the secondary power supply | - During the lamp warm up, set the multimeter to the voltage setting, and insert the leads to GND and HV on the panel beside the secondary power supply | ||
| - | - Once the lamp has warmed up and is waiting for the high voltage to be set, adjust the R202 pot until you are at the correct voltage - Refer to the table below for more info. Press the top left sighting button to when you have set the voltage. | + | - Once the lamp has warmed up and is waiting for the high voltage to be set, adjust the R202 pot until you are at the correct voltage - Refer to the table below for more info. Press the top left sighting button to when you have set the voltage.\\ {{: |
| - The Iris will move to the from the middle to the open position, then back to the middle, Once it is at the middle you may proceed to next voltage | - The Iris will move to the from the middle to the open position, then back to the middle, Once it is at the middle you may proceed to next voltage | ||
| - Repeat until you have completed the High voltage test | - Repeat until you have completed the High voltage test | ||
| Line 26: | Line 27: | ||
| |Photomultiplier serial Number: | |Photomultiplier serial Number: | ||
| |Preame Voltage level|Enter the discriminator (PMT) voltage|52mm PMT are typically around -30mV, where as 22mm PMT are usually around -10mV| | |Preame Voltage level|Enter the discriminator (PMT) voltage|52mm PMT are typically around -30mV, where as 22mm PMT are usually around -10mV| | ||
| - | |Min Voltage|Where to start measuring the high voltage test from|For MB, usually around 900~1000v| | + | |Min Voltage|Where to start measuring the high voltage test from|For MB, usually around |
| - | |Max Voltage|Where to end the high voltage test at|For MV, usually around 1700| | + | |Max Voltage|Where to end the high voltage test at|For MV, usually around |
| |Increment|Increment per level|For MB, 50, for SB, 25| | |Increment|Increment per level|For MB, 50, for SB, 25| | ||
| ^High Voltage(V)^ Measured Voltage(V)^ | ^High Voltage(V)^ Measured Voltage(V)^ | ||
| - | |900|4.5| | + | |900|-4.5| |
| - | |950|4.75| | + | |950|-4.75| |
| - | |1000|5.00| | + | |1000|-5.00| |
| - | |1050|5.20| | + | |1050|-5.20| |
| - | |1100|5.50| | + | |1100|-5.50| |
| - | |1150|5.75| | + | |1150|-5.75| |
| - | |1200|6.00| | + | |1200|-6.00| |
| - | |1250|6.25| | + | |1250|-6.25| |
| - | |1300|6.50| | + | |1300|-6.50| |
| - | |1350|6.75| | + | |1350|-6.75| |
| - | |1400|7.00| | + | |1400|-7.00| |
| - | |1450|7.25| | + | |1450|-7.25| |
| - | |1500|7.50| | + | |1500|-7.50| |
| - | |1550|7.75| | + | |1550|-7.75| |
| - | |1600|8.00| | + | |1600|-8.00| |
| - | |1650|8.25| | + | |1650|-8.25| |
| - | |1700|8.50| | + | |1700|-8.50| |
| - | |1750|8.75| | + | |1750|-8.75| |
| - | |1800|9.00| | + | |1800|-9.00| |
hvb.1661453155.txt.gz · Last modified: 2022/08/25 18:45 by reno