mkiii
This is an old revision of the document!
Table of Contents
MKIII Brewers Quirks and Useful Info
Mainboard Flat Cable Connections
| Cable | Name | Useage |
|---|---|---|
| J2 Top | BA-W77/A | Lamp Board |
| J2 Bottom | BA-W77/B | J1 on hv module |
| J13 Top | BA-W76/B | Iris |
| J13 Bottom | BA-W76/A | Zenith |
| J14 Top | BA-W76/B | Filter wheel #1 |
| J14 Bottom | BA-W76/B | Filter wheel #2 |
| J15 Top | BA-W76/A | Micrometer #2 (MKIII only) |
| J15 Bottom | BA-W76/A | Micrometer #1 |
| J16 Bottom | BA-W76/C | Filter wheel#3 (MK IV only} |
| J17 Top | BA-W76/B | Slitmask (shutter) |
| J17 Bottom | BA-W76/A | Azimuth |
| J12 Top | BA-W76/A | Control switch’s |
| J7 Top | Communication | |
| J7 Bottom | Humidity sensor |
SL/HG adjustments
Disassembly
Spectrometer
To remove the Bulkhead from the spectrometer, there are 4 screws that needs to be removed. *NOTE* Make sure the bulkhead is being held onto before taking all the screws off!
Commands
Frequency used commands in MM
| Command | description |
|---|---|
| I,X | Resets motor X |
| ?motor.ref.high[X] | checks the reference flag of motor X on the high side |
| ?motor.ref.low[X] | checks the reference flag of motor X on the low side |
| ?motor.address.[MOTOR] | checks the motor address used for MOTOR |
K&Z New Electronics
mkiii.1732107249.txt.gz · Last modified: 2024/11/20 12:54 by 127.0.0.1