This is an old revision of the document!
ED
End of Day
At the end of each solar day (solar midnight) it is desirable to summarise, sort, and print out the results of the tests and observations taken the previous day. This may be achieved by using the ED command.
The ED routine:
• summarises data into an “S” file (see SUM).
• sorts and prints data from observations and tests (see OZSUM, FMSUM, FZSUM, HGSUM, SLSUM, UVSUM, ZSSUM).
• prints constants and monitored values (see PO, AP).
• executes a series of tests (see HG, SL, DT, RS, SR, RE, FR)
The first command in ED is a print command, which directs the printout to the printer (see
PN) or to a disk file (see PD). If the operator wishes to change the printing path, either the
ED-PD.RTN or ED-PN.RTN must be copied to ED.RTN.
An operator may run ED at any time. If the Brewer is running in a schedule (see SKC), the
ED command is initiated automatically at solar midnight.
See also ED-PD and ED-PN.