 **A:** Ensure brightest part of the band of light is sitting in the middle of the Iris. There are two ways to accomplish this.++++ More...| **A:** Ensure brightest part of the band of light is sitting in the middle of the Iris. There are two ways to accomplish this.++++ More...|
   - Manually adjusting by loosening the zenith shaft and moving the shaft until the band of light lines up as shown in the picture. \\ {{ :misc:misc:sl_band.png?600 |}}   - Manually adjusting by loosening the zenith shaft and moving the shaft until the band of light lines up as shown in the picture. \\ {{ :misc:misc:sl_band.png?600 |}}
-  - Doing a ZI, this will do a shorten DI where it only checks for the zenith position.\\{{ :misc:misc:misc:zi.jpg?600 |}} As shown on the graph on the right, the zenith is -1 step off. Therefore the Offsets needs to be changed as follows. \\  * Zenith Offset: +1 I.E. Original: 100, New: 101 \\ * UV Offset +1 I.E. Original: 2109, New 2110 \\ * Sighting HC: +1 I.E. Original: -5, New -4 \\ **Note: After changing the sighting, its advisable to have the operator to verify the new sighting.**+  - Doing a ZI, this will do a shorten DI where it only checks for the zenith position.\\ {{:misc:zi.jpg?600|}} \\ As shown on the graph above, the zenith is -1 step off. Therefore the Offsets needs to be changed as follows. \\  * For MB electronics, the offset is clockwise from the reference, so the Zenith Offset: +1 I.E. Original: 100, New: 101\\ * For SB electronics the Zenith Motor origin moves counter clockwise so the Motor.Origin[1]: (gets smaller) Zenith Origin: -1 I.E. Original: 5, New: 4 \\ * UV Offset +1 I.E. Original: 2109, New 2110 \\ * Sighting HC: +1 I.E. Original: -5, New -4 \\ **Note: After changing the sighting, its advisable to have the operator to verify the new sighting.**
 ++++ ++++
  
Line 15: Line 15:
 **A:** {{ :docs:grating_scans.pdf | Troubleshooting Grating Scans}} **A:** {{ :docs:grating_scans.pdf | Troubleshooting Grating Scans}}
  
-==== GVIM ==== 
-**Q:** To remove the ^M\\ 
-**A:** Type: :%s/^M/ /g\\ (note to type in ^M <key>ctrl</key>+<key>v</key> <key>ctrl</key>+<key>m</key>)\\ 
  
 ==== Old Electronics ==== ==== Old Electronics ====
-**Q:** What is the differences between new vs old temperature circuit on the clock board?\\ +**Q:** What are the differences between new vs old temperature circuit on the clock board?\\ 
-**A:** Note the resistors on the top left of the boards below (New Vs Old). New temperature circuits, some resistors has been replaced with a jumper wire. +**A:** Note the resistors on the top left of the boards below (New Vs Old). New temperature circuits, some resistors has been replaced with a jumper wire.\\ 
-{{:pictures:clock_board_old.vs.new.jpg?600|}}+{{:pictures:clock_board_old.vs.new.jpg?600|}}\\
  
 +**Q:** What is the differences between new vs old temperature circuit on the SPS board?\\
 +**A:** Old circuit . Power Supply - R601,604 and 605 are 11M and R602,606 and 607 are 1.6M\\
 +New Sec. Power Supply - R601,604 and 605 are 825K and  R602,606 and 607 are 3M\\
 +
 +**Q:** What pot controls what on the SPS board?\\
 +**A:** {{:pictures:sps_pots.png?400|}}
 +
 +**Q:** What are the jumper settings for board ____?\\
 +**A:** 
 +^Part#^J6^J7^J8^J9^J10^J11^J12^J13^J14^J15^J16^
 +|BA-E50/A|1-2|NC|2-3|2-3|2-3|1-2|1-2|1-2|1-2|2-3|N2|
 +|BA-E50/B|2-3|2-3|1-2|1-2|1-2|1-2|1-2|1-2|1-2|2-3|N4|
 +|BA-E50/D|2-3|2-3|1-2|1-2|1-2|1-2|2-3|2-3|2-3|2-3|N3|
 +|BA-E50/E|1-2|2-3|1-2|1-2|1-2|1-2|2-3|2-3|2-3|2-3|N3|
 +
 +**Q:** What control goes to what connector?\\
 +**A:**
 +^Part#^J1^J2^J3^J4^J5^Applies^
 +|BA-E50/A|NC|Micrometer|Shutter|SPS|NC|MkII & MkIV|
 +|BA-E50/B|Iris|FW#1|FW#2|NC|NC|MkII, MkIII & MkIV|
 +|BA-E50/D|Zenith|Azimuth|FW#3|Control|NC|MkIV|
 +|Ba-E50/E|Zenith|Azimuth|Micrometer#2|Control|NC|MkIII|
 +\\
 ===== Schedules ===== ===== Schedules =====
  
 **Q:** How do you disable the az check at the start of a the schedule?\\ **Q:** How do you disable the az check at the start of a the schedule?\\
-**A:** Inside the skc.rtn, in line 18, add the instrument number you would like the instrument to ignore. Note: You may need to add it into the master program directory or disable the instrument from getting its program updated daily.+**A:** Inside the skc.rtn, in line 11022 (about 18 lines from the top), add the instrument number you would like the program to ignore. Note: You may need to add it into the master program directory or disable the instrument from getting its program updated daily.
  
 ===== Software ===== ===== Software =====
  
-**Q:** How do I remote into _______ site?\\ +**Q:** How do I launch a GUI via remote ssh?\\ 
-**A:** You can connect to most site with [[https://007gc-my.sharepoint.com/:f:/g/personal/reno_sit_ec_gc_ca/EiKYKdxFTDZBsSfJY22y180Bxpj-AjRXzdU8dIpFgm9Brg?e=snqErV|sshvnc]]++ |NoteYou must login to your @ec.gc.ca email and use a compatible browser  to access the files. |++\\ +**A:** Review https://askubuntu.com/questions/47642/how-to-start-a-gui-software-on-a-remote-linux-pc-via-ssh\\ 
-//Note:// SPO requires a few extra stepssee [[spo#vnc|SPO]]+ 
 +**Q:** How do you remove ^M in gvim/vim\\ 
 +**A:** Type: :%s/^M/ /g\\ (note to type in ^M <key>ctrl</key>+<key>v</key> <key>ctrl</key>+<key>m</key>)\\ 
 + 
 +===== DosBox Key Mapper ===== 
 +https://www.dosbox.com/wiki/Mapper\\ 
 +For keyboard issues where up/down/left/right is not workingtry setting setting the following (it may have been set to true) 
 +<code> [sdl] 
 +usescancodes=false</code> 
  